Cooling Tower Specification

  • Connection
  • Flanged or threaded connections based on model requirements
  • Accuracy
  • Maintains water temperature within 2C of set point
  • Pressure
  • Design pressure up to 3 Kg/cm2
  • Function
  • Heat removal from water using evaporation and air flow
  • Size
  • Available in various capacities, typically ranging from 10 TR to 1000 TR
  • Mounting
  • On concrete or steel base support
  • Noise Level
  • Typically less than 70 dB at 1 meter distance
  • Material
  • FRP (Fibre Reinforced Plastic), galvanized steel, or PVC components
  • Fill Media
  • Honeycomb PVC fill for optimal heat transfer
  • Installation
  • Outdoor, skid-mounted
  • Inlet Water Temperature
  • Up to 60C
  • Water Flow Rate
  • 100 LPM to 5000 LPM (varies by model)
  • Power Supply
  • 3-phase AC, 415V, 50Hz
  • Maintenance
  • Low maintenance with easy accessibility
  • Type
  • Induced draft, counterflow design
  • Fan Type
  • Axial flow, direct driven
 

Cooling Tower Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 5000 Pieces Per Month
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

About Cooling Tower



Experience sublime cooling performance with our exclusive range of Cooling Towers, expertly engineered using ineffable FRP, galvanized steel, or PVC components. Featuring a breathtaking induced draft, counterflow design and direct-driven axial fans, these towers ensure optimal heat removal for capacities from 10 TR to 1000 TR (100-5000 LPM). With low maintenance and noise levels under 70 dB, they're ideal for outdoor, skid-mounted installation on concrete or steel bases. Premium honeycomb PVC fill media maximizes heat transfer, while the power supply supports 3-phase AC systems. Reserve yours now-ending soon!

Effortless Operation and Versatile Applications

To use, simply connect the water inlet through the designated flanged or threaded fittings, switch on the 3-phase AC power, and set the required temperature. The tower is designed for easy accessibility and minimal maintenance. Its robust construction and sublime efficiency make it suitable for commercial complexes, factories, and industrial processes needing consistent heat removal. The honeycomb PVC fill ensures optimal cooling, making it perfect for locations where precise temperature control and reliability are vital.


Global Market Delivery and Certification Assurance

Our Cooling Towers are delivered securely packaged for both domestic and international export markets, ensuring minimal expenditure on installation. Serving industries in India and key global regions, we maintain all required certifications so you can trust in quality and safety. Each unit is checked for performance and comes with detailed documentation. With fast delivery and flexible packaging options, these towers are a preferred choice among traders, suppliers, and exporters alike.


FAQ's of Cooling Tower:


Q: How does the induced draft, counterflow design benefit cooling efficiency?

A: The induced draft, counterflow design maximizes heat transfer by allowing air to flow against the water stream, creating a more effective cooling process and maintaining water temperatures within 2C of the set point.

Q: What is the process for installing the cooling tower outdoors?

A: Simply mount the skid-based tower on a concrete or steel base, connect pipework using the appropriate flanged or threaded connections, and ensure the 3-phase AC (415V, 50Hz) supply is accessible. Detailed installation instructions and guidelines are provided for your convenience.

Q: When is the Cooling Tower suitable for use?

A: This cooling tower is ideal for use when you need efficient heat removal from industrial process water, HVAC systems, or large-scale commercial cooling, especially with inlet water temperatures up to 60C.

Q: Where can the cooling tower be utilized most effectively?

A: The tower is most effective in industrial facilities, manufacturing plants, commercial complexes, and anywhere requiring reliable, low-maintenance heat dissipation for water-cooling systems.

Q: What are the main benefits of the honeycomb PVC fill media?

A: The honeycomb PVC fill media offers a large surface area for evaporative cooling, ensuring optimal heat transfer, improved water distribution, and higher cooling efficiency with low water residence time.

Q: How is noise managed with these cooling towers?

A: The axial flow, direct-driven fan system is engineered to maintain noise levels typically under 70 dB at a distance of one meter, making the unit suitable for settings sensitive to sound pollution.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Pressure Instrument Accessories Category

Flushing Ring

Flushing Ring

Minimum Order Quantity : 100 Pieces

Function : Used for flushing, cleaning, or calibration of diaphragm seals and instruments without dismantling; provides connection between process and transmitter for circulatory flow of cleaning or sealing fluids.

Pressure : Suitable for pressure ratings up to 3000 PSI (varies according to design and flange rating)

Size : 1/2 inch to 2 inch (typically available in various sizes as per requirement)

Connection : Flanged, threaded, or customized as per customer requirements; common standards include ANSI, DIN, or BS connections.

Accuracy : Ensures accurate and efficient removal of sediment and contaminants from measurement instruments; dimensional tolerances as per standard specifications.

Overload Protector

Overload Protector

Minimum Order Quantity : 100 Pieces

Function : Prevents electrical equipment from damage due to overload by interrupting the circuit

Pressure : Designed to withstand up to 15 bar (dependent on model)

Size : Standard industrial size, typically compact for easy installation

Connection : Screw terminal connection

Accuracy : High sensitivity for precise overload detection

Pulsation Dampener Adjustable Needle Type

Pulsation Dampener Adjustable Needle Type

Minimum Order Quantity : 100 Pieces

Function : Reduces pulsation and vibration in fluid delivery systems by absorbing pressure fluctuations

Pressure : Designed for operating pressures up to 16 bar

Size : Standard sizes available from 0.1 L to 2 L

Connection : Threaded or flanged connections, compatible with varied pump and piping systems

Accuracy : High precision dampening with minimal pressure deviation

Gauge Cock

Gauge Cock

Minimum Order Quantity : 100 Pieces

Function : To open or shut off passage of fluids in gauge glass or pressure measuring instrument piping.

Pressure : Up to 20 kg/cm2

Size : 1/4 inch to 1 inch

Connection : Screwed (BSP/NPT) or Flanged ends

Accuracy : High shutoff accuracy and minimal leakage